Introduction
Acrylic polymers, mainly poly(methyl methacrylate) (PMMA), are the standard denture-base material. Their clinical behaviour comes from their physical properties: thermal, mechanical, sorption and optical. These properties in turn depend on the polymer's structure and on how it was processed.
Structure that governs the physical properties
Polymers are classified by structure as linear, branched or cross-linked; as amorphous or crystalline; and as thermoplastic or thermoset. PMMA is an amorphous, linear thermoplastic. It becomes partly cross-linked when a cross-linking agent is present in the liquid.
- Higher molecular weight and cross-linking raise strength, rigidity, glass transition temperature (Tg) and craze resistance.
- Residual monomer and other low-molecular-weight substances act as plasticisers: they lower strength, hardness and Tg.
- Heat-cured resin therefore has better properties than cold-cured: higher molecular weight and less residual monomer (about 0.2-0.5% against about 3-5%).
ISO 20795-1 divides denture-base polymers into types:
- Type 1: heat-polymerisable
- Type 2: autopolymerisable
- Type 3: thermoplastic
- Type 4: light-activated
- Type 5: microwave-cured
Thermal properties
- Glass transition temperature (Tg): below it the resin is rigid and glassy; above it, rubbery. Tg of PMMA is about 105 C. Dentures should therefore never be cleaned in boiling water, because internal stresses are released and the denture warps.
- Thermal conductivity is very low (about 0.2 W/m K). The base insulates the palate, which reduces the patient's sense of temperature, so very hot drinks may be swallowed unnoticed.
- Coefficient of thermal expansion is high, about 80 \times 10^{-6} per C, several times that of enamel and of porcelain teeth. Consequences are thermal shrinkage after processing and stress around porcelain teeth.