Dental Materials · MU Plovdiv

47. Cold-curing (auto-curing) acrylic resins.

Inside: 5 sections · 1 labelled picture · 1 table · 15 flashcards · 2 min

Topic 47 of 85 in the MU Plovdiv syllabus for Dental Materials (Dental Medicine, Year 1). The free AceMed note covers it in 5 sections, about 196 words (2 min of reading), with 15 flashcards.

In this note

  1. Introduction
  2. How they differ in composition
  3. Setting
  4. Properties
  5. Variations

Introduction

Cold-cured polymers, also known as self-curing, quick-curing or auto-curing resins, polymerize when a chemical activator splits the initiator. No heat is needed, which makes them convenient for repairing broken or defective dentures.

How they differ in composition

  • Liquid: the same as in heat-cured resin, plus an activator. The most common is dimethyl-para-toluidine, at up to 0.75%. Tertiary amines, sulfonic acids and salts of sulfinic acids can also act as activators.
  • Powder: the same as in heat-cured resin, but with more initiator, up to 1.5%.

Setting

The activator rapidly breaks down the initiator. Chains stop growing after 10 to 20 minutes. Temperature has a large effect: the reaction almost stops at 5 °C, and above 30 °C it speeds up, with the mix reaching up to 90 °C. The resin is usually cured in the open air without pressure.

Properties

Because the reaction is fast, the chains are shorter. Cold-cured resin therefore has lower density and weaker mechanical and biological properties than heat-cured resin.

  • Higher solubility, water uptake and toxicity: more monomer remains free.
  • More porosity: there is no pressure during curing.
  • Color change: nitrogen compounds in the activator oxidize, and the products stain the resin yellow-brown.
  • Allergy: oxidized activator can cause allergic reactions.