Introduction
Peripheral equipment means the devices that supply the dental unit with compressed air, vacuum, water and power, and the devices connected to or serving it, such as handpieces, accessory devices and reprocessing equipment. Both the quality of the work and the safety of patients and staff depend on this equipment and on its maintenance.
Overview and classification
- Supply equipment: compressor with air dryer and filters; vacuum (suction) unit with separator; amalgam separator; water supply and treatment.
- Equipment connected to the unit: air turbine, micromotor with straight and contra-angle handpieces, three-way syringe, ultrasonic scaler, light-curing unit, intraoral camera, electrosurgery unit.
- Reprocessing equipment: ultrasonic cleaner, washer-disinfector, a handpiece maintenance device (cleaning and oiling), steam sterilizer (autoclave) and sealing machine.
- Imaging: intraoral X-ray unit with a sensor or phosphor plate; panoramic or CBCT units (named only).
The compressor and suction motor belong in a separate, ventilated technical room because of noise and heat.
Compressor and compressed air
An oil-free compressor is preferred. Medical-grade air must be dry, oil-free and filtered. Moisture and oil contaminate the surfaces to be bonded or cemented and damage turbine bearings.
- Parts: motor and pump, tank (receiver), pressure switch, safety valve, air dryer (membrane or adsorption type), filters and a condensate drain.
- The compressor is sized to the number of units running at the same time.
- Air turbines run on an air pressure of about 2–3 bar.
- Maintenance: drain the condensate, change the filters, and service as the manufacturer instructs.