Dental Materials · MU Sofia

44. Composite materials. Light-curing and dual-curing composites

Introduces composites as resin and filler materials and traces their development from Bis-GMA to blue-light curing. Classifies them by filler size with a comparison table of strength, modulus, hardness and polishing, then by curing method covering chemically cured, light-cured and dual-cured types. Explains polymerization shrinkage, the C-factor with cavity examples, and strategies for reducing shrinkage stress, followed by brief notes on compomers and giomers.

Inside: 6 sections · 2 labelled pictures · 2 tables · 14 flashcards · 2 min

Topic 44 of 52 in the MU Sofia syllabus for Dental Materials (Dental Medicine, Year 1). The free AceMed note covers it in 6 sections, about 225 words (2 min of reading), with 14 flashcards.

In this note

  1. Introduction
  2. Classification by filler
  3. Classification by curing
  4. Polymerization shrinkage
  5. Reducing shrinkage stress
  6. Related materials

Introduction

Composite materials combine organic resins with inorganic fillers, which do not dissolve in each other. R. Bowen developed Bis-GMA around 1960. The first self-cured composite appeared in 1962, and blue-light curing followed in 1978. Composites are now the most used filling materials.

Classification by filler

  • Nanofilled: very high polish and wear resistance, and they keep their gloss.
  • Nanohybrid: the latest generation, universal for anterior and posterior teeth, with excellent esthetics, handling and wear.

Polymerization shrinkage

Only the resin polymerizes, and it shrinks as it does. Stress reaches about 7 MPa and can break the bond, causing gaps, sensitivity and secondary caries. A self-cured composite shrinks toward its center, while a light-cured one shrinks toward the light.

The C-factor is the ratio of bonded to free surfaces of a restoration. The higher it is, the less the material can flow to relieve stress.

Reducing shrinkage stress

  • Incremental placement: small layers, each cured through the tooth wall.
  • Soft-start curing: for example, 10 seconds at 150 mW/cm², then 700 mW/cm².
  • Pulse curing: short, intense pulses of light.
  • Flowable liner: a thin layer of low-modulus composite, about 5 GPa, acts as an elastic buffer.
  • New chemistry: ormocers shrink about 2%, and siloranes less than 1%.

Continue reading free